Radiator and Section Quantity Calculator

Formula

ceil(Room design heat loss / (Output correction factor × Output per radiator or section))

Planning estimate. Check product specifications and local requirements before purchasing.

Worked example: Radiator Output Calculator

Measurements in this example

Room design heat loss3200 W
Output per radiator or section160 W
Output correction factor0.85

Calculated quantities

Required nominal output3.76 kW
Radiators or sections24

What to check

This calculation uses: Room design heat loss, Output per radiator or section, Output correction factor. It returns: Required nominal output, Radiators or sections.

Published radiator output normally assumes a stated water and room temperature regime. Apply the appropriate manufacturer correction.

This simplified estimate is useful for planning. A room-by-room fabric and ventilation calculation is needed for final system design.

Use the units beside each field. The values in the worked example are starting inputs; replace them with your measurements and the specifications of your material.